| Digital inputs | V | 0…2.7 “OFF” (0); 3.3…30 “ON” (1) |
| Maximum power dissipation D-In 2 & 3 | mW | 5 |
| Supply voltage | V | DC 18 … 30, recommended: 24 |
| Current consumption | mA | max. 100 @ 24 VDC |
| Output voltage | V | nominal -10 … 10 (maximum -12 … 12) |
| Overload limit charge input | % | 200 |
| Operating temperature range | °C | -20 … 70 |
| Protection class according to DIN EN 60529 (with cable connected) | IP67 | |
| Weight | g | 135 |